Product Categories

YFHI-01 Heating Incubator

YFHI-01 Heating Incubator

YFHI-01 Heating Incubator Other Equipment Laboratory Equipment

Product Details

Technical Parameters(Natural Convection)

Capacity(L) 34L 54L 124L 222L
Temp Range RT+5 - 80℃
Stability ±0.2℃
Uniformity(at 37℃ ) ±0.8℃
Display Resolution 0.1℃
Max number of shelves 2(5) 2(6) 2(10) 2(16)
Max load per shelf 20Kg
NW 44Kg 53Kg 79Kg 108Kg
Timing Range 1 - 5999mins
Interior Dimension
W×D×H(mm)
320×340×320 400×360×415 520×480×490 650×540×650
Exterior Dimension
W×D×H(mm)
610×520×580 690×468×640 810×588×755 940×658×910
Electrical Requirement AC220V/50Hz
Power Consumption 250W 300W 550W 700W
 

Technical Parameters(Air Forced)

Capacity(L) 35L 67L 146L 253L
Temp Range RT+5 - 80℃
Stability ±0.2℃
Uniformity(at 37℃ ) ±0.8℃
Display Resolution 0.1℃
Max number of shelves 2(5) 2(9) 2(12) 2(16)
Max load per shelf 20Kg
NW 48Kg 56Kg 82Kg 119Kg
Timing Range 1 - 5999mins
Interior Dimension
W×D×H(mm)
320×390×320 400×395×415 520×510×530 650×600×650
Exterior Dimension
W×D×H(mm)
610×550×545 690×560×640 810×685×755 940×755×875
Electrical Requirement AC220V/50Hz
Power Consumption 300W 350W 600W 700W
 

Technical Configuration

● Adopting direct heating system, the heating speed is fast and the control precision is high.
● PID control technology, high control precision and small temperature fluctuation.
● Available in Chinese and English menus to meet different language needs, with °C / °F conversion.
● The height of the shelf is adjustable to meet different cultivation needs.
● Professional stacking foot design, the machine can be stacked, saving lab space and improving the use efficiency (same specification).
● Protection on instruments: Comply international standard secondary temp limiting alarm system. When the heating is out of control or exceeds the maximum limit temperature, the heating is automatically cut off with sound and light alarm.
● Protection on key components: Key components are equipped with over-current, over-temperature, overload and other safety protection.
● Protection on samples: When the temperature inside the box is higher or lower than the set temperature, the alarm will start to cut off the heater, with sound and light alarm to remind the operator to protect the sample from normal test without accident.
● Protection on operator: The cabinet and door are specially insulated to make the surface temperature of the cabinet low, ensuring the operator's safety.
● Breakdown message provided: When the instrument breakdown, the message will shown on the screen to help operator clearly check.
● The touch screen type standard with a USB interface, which can record the change status of the temperature parameters.
● LCD screen is option for USB interface.
● Can realize remote control of the machine through software (option).




 

Related Products